Dual Rheem Endeavor Install & Quality Inspection in Las Vegas Attic
At Fast Affordable Air, we recently completed a comprehensive air conditioning upgrade for a home in Las Vegas. This project involved installing not one, but two Rheem Endeavor central air conditioning systems — each rated at 3 tons and 14.3 SEER2 efficiency — with matching gas furnaces.
Project Overview
The customer’s home needed more reliable and energy-efficient heating and cooling. The original systems were outdated and showing signs of wear, including uneven cooling, high energy bills, and longer run times. We recommended and installed two brand-new Rheem Endeavor systems. These units offer dependable performance, advanced airflow, and improved energy savings.
Installation Details
We started in the attic by removing the old air handlers and duct transitions. The new Rheem gas furnaces were mounted horizontally and suspended securely with support rods and platforms to ensure proper drainage and clearance. You’ll notice in the photos that each furnace is paired with a custom plenum, tightly sealed with duct mastic to prevent air leakage and keep efficiency high.
Both systems are connected to insulated flexible ductwork. These ducts are designed to reduce energy loss and improve overall indoor air distribution. Every connection was taped, sealed, and secured per manufacturer and code requirements.
Drainage and Condensate Lines
High-efficiency AC systems like these generate a significant amount of condensate (water formed when warm air is cooled). To prevent attic water damage, we installed a dual drain system: a primary drain line for normal operation and a secondary overflow drain with a safety cutoff switch — also called a float switch. This switch shuts off the system if water starts backing up, which helps avoid ceiling leaks.
Outdoor Units
Outside the home, we placed both Rheem condensers side by side on new concrete pads. Each condenser is a 3-ton unit that matches the furnace inside. These condensers pull heat out of the home during summer months and work seamlessly with the indoor gas furnace.
All line sets and electrical disconnects were professionally installed to meet Las Vegas HVAC code. The units were charged with R-410A refrigerant, properly pressure-tested, and leak-checked to ensure reliable cooling all summer long.
Quality Control Inspection
Before finalizing the install, we performed a complete quality control inspection. This includes:
- Inspecting and tightening gas line connections
- Verifying refrigerant pressures with a manifold gauge set
- Checking airflow at supply and return registers
- Verifying the operation of the thermostat and control board
- Testing all safety switches, including the condensate float switches
These inspections ensure the systems run safely and meet performance standards. They also help extend the life of the air conditioners and reduce the chance of breakdowns later on.
Benefits for the Homeowner
By installing dual 3 Ton 14.3 SEER2 Rheem Endeavor systems, the homeowner now enjoys:
- Improved comfort in every room
- Lower energy bills thanks to higher SEER2 efficiency
- Reliable cooling during extreme Las Vegas summers
- Quiet operation from both indoor and outdoor units
- Enhanced safety and peace of mind with proper drain and electrical systems
Learn more about our air conditioning installation services and why so many homeowners in Clark County trust Fast Affordable Air for expert HVAC solutions.